E91
AEG
No Communication Between Main PCB and User Interface
Display shows E91, buttons may not respond correctly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose or damaged UI ribbon cable, Faulty user interface board, Faulty main PCB communication circuit, Moisture ingress in control panel
How to Fix / Troubleshooting
Safety: Disconnect power before removing the control panel.
- Inspect ribbon cable: Remove the control fascia and check the flat cable between the UI and main board. Reseat both ends and ensure no kinks or cracks.
- Dry moisture: If the panel has been exposed to steam or leaks, allow it to dry completely.
- Replace UI board: If connections are good but E91 persists, replace the AEG user interface board. If still unresolved, the main PCB may also need replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
AEG User Interface Board
Check Price on Amazon