E60
Bush
General Drying System Error
Washer-dryer shows E60 during drying; drying performance is poor or non-existent.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dryer heater fault, Blocked condenser, Faulty dryer fan, Defective dryer temperature sensor
How to Fix / Troubleshooting
Safety first: Unplug and allow the appliance to cool before working on the dryer system.
- Clean condenser and ducts: If your Bush model has a removable condenser, take it out and rinse thoroughly. Otherwise, access internal ducts and carefully remove lint build-up.
- Check dryer fan operation: Start a drying cycle and listen for the fan. If silent, inspect the fan motor and wiring.
- Inspect dryer thermostats and sensor: Check that all connectors on the heater housing and temperature sensor are secure.
- Replace faulty parts: If the heater is open-circuit or the fan does not run, replace the defective component with Bush-compatible dryer heater, fan motor, or NTC sensor.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Dryer Heater Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements