E18
Caple Water Level Calibration / Sensor Range Fault

Washer-dryer shows E18 and stops; water level in drum appears incorrect for the selected program.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty pressure sensor, Blocked pressure chamber on tub, Kinked or split pressure hose, Incorrect sensor signal to PCB

How to Fix / Troubleshooting

Safety first: Unplug the appliance and turn off water supply before working on the pressure system.

  • Step 1 – Inspect pressure hose: Remove the top cover and locate the pressure switch and its hose. Check for kinks, splits, or disconnections.
  • Step 2 – Clean pressure chamber: Follow the hose down to where it connects to the tub or pressure chamber. Remove and clean any soap scum or sludge that may block the air path.
  • Step 3 – Reset sensor: After cleaning, reconnect the hose securely and run a rinse cycle to see if E18 clears.
  • Step 4 – Replace pressure sensor: If the error persists, replace the pressure switch with a Caple-compatible water level sensor.
  • Step 5 – Professional calibration: Some models may require sensor calibration via service mode, which should be performed by a Caple technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Water Level Pressure Switch
Check Price on Amazon