Caple
Random Program Interruption
Washer-dryer stops mid-cycle without draining or spinning; no error code is displayed.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Overheating of motor or PCB, Intermittent door lock contact, Loose wiring harness connection, Software glitch in control board
How to Fix / Troubleshooting
Safety first: Unplug the appliance before checking internal connections.
- Step 1 – Note conditions: Observe whether stoppage occurs at the same point (e.g. after heating or during spin).
- Step 2 – Door lock: Check that the door lock is secure and not loose. Replace if intermittent.
- Step 3 – Wiring harness: Inspect connectors on motor, heater, pump, and PCB for looseness.
- Step 4 – Ventilation: Ensure the machine has adequate ventilation and is not overheating in a confined space.
- Step 5 – If recurring: The main PCB may require replacement or firmware update by a Caple technician.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Door Lock Assembly
Check Price on Amazon