E19
Ikea
Diverter Valve / Drying Water Valve Fault
Washer-dryer shows E19; may be related to internal valve switching for wash/dry
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty diverter valve coil, Blocked diverter valve, Loose wiring to diverter, Control board output failure
How to Fix / Troubleshooting
Safety first: Unplug the appliance and close the water tap before internal inspection.
Step-by-step checks:
- 1. Locate diverter valve: Some Ikea washer-dryer combos use a diverter valve to control water flow for drying condenser cooling. It is usually near the inlet valve or sump.
- 2. Inspect for blockage: Remove hoses from the diverter and check for scale or debris. Clean thoroughly.
- 3. Test coil: Measure resistance across the diverter coil. An open circuit indicates failure; replace the valve.
- 4. Check wiring: Ensure connectors are tight and wires are not damaged.
- 5. Control board: If the valve is good but not being energized, the PCB output may be faulty and require technician diagnosis.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Diverter Valve
Check Price on Amazon
We may earn a commission from links on this page.