FE
LG
Water Overflow / Fill Level Error
Washer-dryer combo overfills with water or shows FE; water may be visible in drum when unit is off.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck-open water inlet valve, Blocked or kinked pressure hose, Faulty water level pressure sensor, Defective main control board
How to Fix / Troubleshooting
Safety first: Unplug the unit and turn off both water supply valves immediately to stop filling.
- 1. Stop water flow:
- Close hot and cold water faucets.
- Use a wet/dry vacuum or manual draining via the pump filter to remove excess water if needed.
- 2. Check water inlet valve:
- With water supply off and unit unplugged, disconnect hoses and inspect for debris.
- If water continues to flow into the tub when the unit is unplugged but water valves are open, the LG inlet valve is stuck open and must be replaced.
- 3. Inspect pressure hose and sensor:
- Remove the top cover.
- Locate the small rubber or plastic pressure hose running from the tub/air chamber to the pressure sensor.
- Ensure the hose is not kinked, cracked, or disconnected.
- Blow gently through the hose to clear any blockage (do not use high pressure).
- Check the pressure sensor connection and replace the sensor if FE persists.
- 4. Control board evaluation:
- If the inlet valve and pressure system are good, the main PCB may be misreading the level signal.
- Board replacement should be done by a qualified technician.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
LG Water Inlet Valve Assembly
Check Price on Amazon
We may earn a commission from links on this page.