E23
Midea
Drain Pump Triac / Control Fault
Washer-dryer combo displays E23 and may not drain or may show intermittent drain issues.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Shorted drain pump drawing excessive current, Damaged wiring harness to pump, Failed triac or driver circuit on main PCB, Moisture on control board
How to Fix / Troubleshooting
Safety first: Unplug the appliance before inspecting electrical components.
- Inspect pump and wiring: Check the drain pump for signs of overheating or burning. Inspect the harness for melted insulation or shorts to chassis.
- Test pump current draw (advanced): Using a clamp meter and proper safety precautions, measure pump current during operation. Excessive current suggests a failing pump.
- Check control board: Remove the main PCB cover and look for burned components near the pump triac area.
- Replace faulty parts: If the pump is shorted, replace it and re-test. If the board is visibly damaged or E23 persists with a good pump, the main PCB will likely need replacement.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Main Control Board (PCB)
Check Price on Amazon