E31
Midea Pressure Sensor Calibration / Signal Error

Washer-dryer combo displays E31 and may not fill or may overfill; water level readings are erratic.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty analog pressure sensor, Damaged sensor wiring, Blocked air hose or chamber, Incorrect sensor voltage from PCB

How to Fix / Troubleshooting

Safety first: Unplug the unit before accessing the sensor and wiring.

  • Inspect pressure hose and chamber: As with E7, ensure the hose is clear and the air chamber on the tub is not clogged.
  • Check wiring harness: Verify the connector at the Midea analog pressure sensor is secure and wires are not pinched or cut.
  • Sensor replacement: If hoses and wiring are good but E31 persists, replace the pressure sensor with the correct Midea part.
  • Service mode (if available): Some models allow sensor calibration in service mode; refer to service documentation. Incorrect calibration should be handled by a technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Analog Water Level Sensor