E9
Midea Water Overflow / Overfill Protection

Washer-dryer combo displays E9 and may stop with water still in the drum or show erratic water levels.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck water inlet valve letting water in continuously, Blocked pressure hose causing incorrect level reading, Faulty water level sensor, Main PCB not shutting off valve

How to Fix / Troubleshooting

Safety first: Unplug the appliance immediately and close the water supply taps if water continues to enter the drum.

  • Observe behavior: If water keeps filling even when the machine is off, the inlet valve is likely stuck open mechanically.
  • Inspect inlet valve: Remove the top cover and locate the Midea water inlet valve. Check for debris or scale that may prevent the valve from closing.
  • Check pressure system: Inspect the pressure hose and sensor as described for E7. A blocked hose can cause the control to think the drum is not full yet.
  • Test valve electrically: With power disconnected, measure coil resistance. If coils are in range but valve leaks water when de-energized, replace the valve assembly.
  • Do not use until fixed: Overfilling can cause flooding. Replace any faulty components before resuming normal operation.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Water Inlet Valve Assembly
Check Price on Amazon