Vedette Door Interlock Stuck Closed

Washer-dryer door will not open at the end of the cycle, but there is no error code.

Advertisements

Possible Causes

Door lock mechanism jammed, Control board not sending unlock signal, Residual water detected in drum by pressure switch, High drum temperature after drying

How to Fix / Troubleshooting

Safety first: Do not force the door open; you may break the latch or glass.

  • Step 1 – Wait and cool: After a drying cycle, the door may remain locked until the drum cools. Wait 5–10 minutes.
  • Step 2 – Check for water: If water is visible in the drum, drain via the drain filter and then try opening again.
  • Step 3 – Power reset: Turn the machine off, unplug for 5 minutes, then plug back in and try to open.
  • Step 4 – Emergency release: Use the manual door release near the drain filter (if fitted) to open the door.
  • Step 5 – Inspect door lock: If the problem recurs, replace the door lock assembly as described earlier.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Lock Assembly
Check Price on Amazon

We may earn a commission from links on this page.