Vedette
Door Interlock Stuck Closed
Washer-dryer door will not open at the end of the cycle, but there is no error code.
Advertisements
Possible Causes
Door lock mechanism jammed, Control board not sending unlock signal, Residual water detected in drum by pressure switch, High drum temperature after drying
How to Fix / Troubleshooting
Safety first: Do not force the door open; you may break the latch or glass.
- Step 1 – Wait and cool: After a drying cycle, the door may remain locked until the drum cools. Wait 5–10 minutes.
- Step 2 – Check for water: If water is visible in the drum, drain via the drain filter and then try opening again.
- Step 3 – Power reset: Turn the machine off, unplug for 5 minutes, then plug back in and try to open.
- Step 4 – Emergency release: Use the manual door release near the drain filter (if fitted) to open the door.
- Step 5 – Inspect door lock: If the problem recurs, replace the door lock assembly as described earlier.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Door Lock Assembly
Check Price on Amazon