E32
Hisense
Pressure Sensor Calibration / Range Error
Washer displays E32, water level reading unstable, frequent fill and drain
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty pressure sensor, Blocked air chamber on tub, Kinked or pinched pressure hose, Control board calibration fault
How to Fix / Troubleshooting
Safety first: Disconnect power before removing the top cover.
- Clean pressure system: Remove the pressure hose from the sensor and tub. Check for soap scum or lint blockage. Clean with warm water and reattach.
- Inspect air chamber: At the tub connection, ensure the air chamber is not clogged with detergent residue. Clean if accessible.
- Check hose routing: Ensure the hose is not pinched under the top cover or by internal components.
- Replace sensor if needed: If E32 persists, replace the pressure sensor with a Hisense-compatible part.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Water Level Pressure Sensor
Check Price on Amazon
We may earn a commission from links on this page.