A05
Ferroli Air Pressure Switch / Fan Fault

Error A05 appears, unit attempts to start but shuts down, sometimes accompanied by fan operation anomalies.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked flue or condensate trap, Faulty air pressure switch, Cracked or disconnected pressure tubing, Defective fan motor

How to Fix / Troubleshooting

Safety: Disconnect power and ensure the appliance is cool before working on the flue or fan.

  • 1. Check flue and terminal: Make sure the Ferroli concentric flue is not blocked or crushed. Clear any debris from the terminal.
  • 2. Inspect condensate trap (on condensing models): Remove and clean the condensate trap and hoses. A blocked trap can affect pressure readings.
  • 3. Examine pressure switch tubing: Locate the air pressure switch and its silicone tubes. Ensure they are firmly connected, not split, and free of water. Replace any hardened or cracked tubing.
  • 4. Listen to fan operation: On startup, the fan should run smoothly. If it does not start, is noisy, or stops abruptly, the fan assembly may be failing and should be replaced.
  • 5. Test pressure switch (technician): A professional can test the switch with a manometer or continuity meter to confirm operation and replace it if faulty.

Do not modify or bypass the air pressure switch; it is a critical safety device.