A06
Ferroli Flow Temperature Overheat

Display shows A06, burner shuts down during operation, often after running for a short period.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Scaled heat exchanger reducing flow, Insufficient water flow through heater, Faulty flow temperature NTC, Circulation issues in system (for integrated systems)

How to Fix / Troubleshooting

Safety: Turn off power and allow the unit to cool before touching pipework or internal components.

  • 1. Check water flow: Open a hot tap fully and observe flow. Very low flow can cause rapid overheating. Clean or replace inlet filters and aerators on taps.
  • 2. Inspect system valves: Ensure all isolation valves on the cold inlet and hot outlet of the Ferroli heater are fully open.
  • 3. Descale heat exchanger: In hard water areas, the plate or primary heat exchanger can scale up. A technician should isolate the heater and flush the heat exchanger with an approved descaling solution.
  • 4. Check flow NTC sensor: Locate the flow temperature sensor on the outlet pipe or heat exchanger. Inspect for damage and secure contact with the pipe. Replace if readings are erratic or out of specification.
  • 5. System circulation (for models with pump): Verify that the internal pump runs and that there are no airlocks. Bleed air from high points if necessary.
Advertisements

Repair Difficulty

Hard 4/5