F01
Ferroli
Domestic Hot Water NTC Sensor Fault
Error F01, water temperature reading is clearly wrong (e.g., shows very high or very low when water is lukewarm).
Advertisements
Possible Causes
Open-circuit DHW NTC, Shorted DHW NTC, Poor thermal contact between sensor and pipe, Damaged sensor wiring
How to Fix / Troubleshooting
Safety: Turn off power and allow pipes to cool before touching.
- 1. Locate DHW NTC: On Ferroli water heaters, the DHW sensor is usually clipped to the hot outlet pipe or integrated into a sensor pocket.
- 2. Check mounting: Ensure the sensor is firmly attached and that any thermal paste or clip is intact.
- 3. Inspect cable: Look for cuts, kinks, or signs of overheating. Reseat the connector on the PCB.
- 4. Replace sensor: If the sensor is physically damaged or readings are unstable, replace it with the correct Ferroli DHW NTC.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
DHW NTC Sensor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements