E007
GSW Low Voltage / Power Supply Error

GSW electronic gas water heater shows E007 and the display is blank or flickering

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose power connection, Faulty transformer or power cord, Control board failure, Tripped internal fuse

How to Fix / Troubleshooting

Safety: Turn off power at the breaker before opening any electrical compartment.

  • Verify supply voltage: Confirm the outlet or junction box feeding the heater has the correct voltage (typically 120 V AC). Reset any tripped breaker or GFCI.
  • Inspect power cord and wiring: Look for cuts, burns, or loose wire nuts at the junction box. Tighten connections and replace damaged cords.
  • Check internal fuse (if equipped): Some GSW control boards have a small replaceable fuse. Remove the control cover and visually inspect the fuse. Replace only with the same rating if blown.
  • Transformer / power module: If the unit uses an external transformer, test its output with a multimeter. Replace if no or low output is measured.
  • Control board replacement: If proper power is present but the display remains blank or E007 persists, the control board is likely defective and should be replaced with a GSW-approved board by a qualified technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Control Board
Check Price on Amazon