E001
Electronic GSW gas water heater will not ignite; display shows E001 and burner never lights
Ignition Failure Lockout
E002
GSW power vent gas water heater shows E002 and the blower starts then shuts off without ignition
Pressure Switch / Venting Fault
E003
GSW electronic gas water heater displays E003 and shuts down shortly after ignition
Flame Loss / Flame Sensing Error
E004
GSW power vent water heater shows E004 and the blower does not start
Blower Motor / Inducer Failure
E005
GSW electronic gas water heater shows E005 and will not attempt ignition
High Limit / ECO (Energy Cut-Off) Tripped
E006
GSW power vent water heater displays E006 and cycles the blower without ignition
Air Intake Blockage / Combustion Air Fault
E007
GSW electronic gas water heater shows E007 and the display is blank or flickering
Low Voltage / Power Supply Error
E008
GSW gas water heater shows E008 and shuts down with very hot water at the taps
Temperature Sensor Out of Range (Overtemperature)
E009
GSW power vent water heater displays E009 and the unit locks out after several failed starts
Ignition Retry Lockout
E010
GSW electronic gas water heater shows E010 and the burner shuts off before reaching set temperature
Thermostat / Sensor Communication Error
E011
GSW power vent water heater displays E011 and the blower runs continuously without firing
Stuck Pressure Switch / Vent Proving Fault
E012
GSW electronic gas water heater shows E012 and the unit will not power up after a surge or outage
Control Board Internal Fault
E013
GSW power vent water heater displays E013 and shuts down during operation on very cold days
Intake / Exhaust Temperature Fault
E014
GSW electronic gas water heater shows E014 and the burner will not light after the tank has been drained and refilled
Dry-Fire Protection / No Water Detected (primarily on electric models, but some controls monitor fill state)
E101
GSW electric water heater with electronic control shows E101 and no hot water
Upper Heating Element Circuit Open
E102
GSW electric water heater shows E102 and water is only lukewarm
Lower Heating Element Circuit Open
E103
GSW electric water heater displays E103 and trips the breaker when heating
Element to Ground Short
E104
GSW electric water heater with digital display shows E104 and water is excessively hot
Thermostat / Sensor Stuck Closed
E105
GSW electric water heater shows E105 and no hot water after a power outage
High Limit (ECO) Tripped
E201
GSW hybrid or high-efficiency electric water heater shows E201 and runs only on backup elements
Heat Pump Module Fault
Symptom
GSW electric water heater has hot water but recovery is very slow
Single Element Operation / Lower Element Failure
Symptom
GSW electric water heater has no hot water at all
Total Power / Upper Circuit Failure
Symptom
GSW gas water heater burner does not light even though the pilot is on (standing pilot models)
Gas Control Valve / Thermostat Failure
Symptom
GSW gas water heater pilot will not light or stay lit (standing pilot models)
Pilot Flame / Thermocouple Failure
Symptom
GSW gas water heater produces insufficient hot water or runs out quickly
Capacity / Thermostat / Dip Tube Issue
Symptom
GSW power vent water heater is very noisy (whining or rattling) during operation
Blower / Inducer Noise
Symptom
GSW water heater causes water hammer or banging noises in pipes when heating or when taps close
Hydraulic Shock / Expansion Noise
Symptom
GSW water heater does not meet temperature at distant fixtures but is hot near the tank
Distribution / Recirculation / Piping Issue
Symptom
GSW water heater emits a rotten egg or sulfur smell from hot water taps
Bacterial Reaction with Anode Rod
Symptom
GSW water heater leaks from the drain valve at the bottom of the tank
Leaking Drain Valve
Symptom
GSW water heater leaks from the side or bottom of the tank body (not from fittings)
Tank Corrosion / Inner Tank Rupture
Symptom
GSW water heater leaks from the top around the hot or cold connections
Leaking Nipple / Dielectric Union / Dip Tube Connection
Symptom
GSW water heater makes popping, rumbling, or banging noises during heating
Sediment Boiling / Scale Buildup
Symptom
GSW water heater outer jacket is very hot to the touch or insulation seems inadequate
Insulation Degradation / Overheating
Symptom
GSW water heater produces discolored (rusty or brown) hot water
Internal Corrosion / Anode Depletion
Symptom
GSW water heater shows signs of backdrafting (soot around draft hood, melted plastic, or exhaust smell)
Vent Draft / Combustion Spillage
Symptom
GSW water heater T&P (temperature and pressure) relief valve is dripping or discharging water
Excessive Pressure / Temperature or Faulty T&P Valve
Symptom
GSW water heater trips the GFCI or AFCI outlet/breaker intermittently
Ground Fault / Electrical Leakage
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| E001 |
Electronic GSW gas water heater will not ignite; display shows E001 and burner never lights
|
Ignition Failure Lockout | View Details |
| E002 |
GSW power vent gas water heater shows E002 and the blower starts then shuts off without ignition
|
Pressure Switch / Venting Fault | View Details |
| E003 |
GSW electronic gas water heater displays E003 and shuts down shortly after ignition
|
Flame Loss / Flame Sensing Error | View Details |
| E004 |
GSW power vent water heater shows E004 and the blower does not start
|
Blower Motor / Inducer Failure | View Details |
| E005 |
GSW electronic gas water heater shows E005 and will not attempt ignition
|
High Limit / ECO (Energy Cut-Off) Tripped | View Details |
| E006 |
GSW power vent water heater displays E006 and cycles the blower without ignition
|
Air Intake Blockage / Combustion Air Fault | View Details |
| E007 |
GSW electronic gas water heater shows E007 and the display is blank or flickering
|
Low Voltage / Power Supply Error | View Details |
| E008 |
GSW gas water heater shows E008 and shuts down with very hot water at the taps
|
Temperature Sensor Out of Range (Overtemperature) | View Details |
| E009 |
GSW power vent water heater displays E009 and the unit locks out after several failed starts
|
Ignition Retry Lockout | View Details |
| E010 |
GSW electronic gas water heater shows E010 and the burner shuts off before reaching set temperature
|
Thermostat / Sensor Communication Error | View Details |
| E011 |
GSW power vent water heater displays E011 and the blower runs continuously without firing
|
Stuck Pressure Switch / Vent Proving Fault | View Details |
| E012 |
GSW electronic gas water heater shows E012 and the unit will not power up after a surge or outage
|
Control Board Internal Fault | View Details |
| E013 |
GSW power vent water heater displays E013 and shuts down during operation on very cold days
|
Intake / Exhaust Temperature Fault | View Details |
| E014 |
GSW electronic gas water heater shows E014 and the burner will not light after the tank has been drained and refilled
|
Dry-Fire Protection / No Water Detected (primarily on electric models, but some controls monitor fill state) | View Details |
| E101 |
GSW electric water heater with electronic control shows E101 and no hot water
|
Upper Heating Element Circuit Open | View Details |
| E102 |
GSW electric water heater shows E102 and water is only lukewarm
|
Lower Heating Element Circuit Open | View Details |
| E103 |
GSW electric water heater displays E103 and trips the breaker when heating
|
Element to Ground Short | View Details |
| E104 |
GSW electric water heater with digital display shows E104 and water is excessively hot
|
Thermostat / Sensor Stuck Closed | View Details |
| E105 |
GSW electric water heater shows E105 and no hot water after a power outage
|
High Limit (ECO) Tripped | View Details |
| E201 |
GSW hybrid or high-efficiency electric water heater shows E201 and runs only on backup elements
|
Heat Pump Module Fault | View Details |
| – |
GSW electric water heater has hot water but recovery is very slow
|
Single Element Operation / Lower Element Failure | View Details |
| – |
GSW electric water heater has no hot water at all
|
Total Power / Upper Circuit Failure | View Details |
| – |
GSW gas water heater burner does not light even though the pilot is on (standing pilot models)
|
Gas Control Valve / Thermostat Failure | View Details |
| – |
GSW gas water heater pilot will not light or stay lit (standing pilot models)
|
Pilot Flame / Thermocouple Failure | View Details |
| – |
GSW gas water heater produces insufficient hot water or runs out quickly
|
Capacity / Thermostat / Dip Tube Issue | View Details |
| – |
GSW power vent water heater is very noisy (whining or rattling) during operation
|
Blower / Inducer Noise | View Details |
| – |
GSW water heater causes water hammer or banging noises in pipes when heating or when taps close
|
Hydraulic Shock / Expansion Noise | View Details |
| – |
GSW water heater does not meet temperature at distant fixtures but is hot near the tank
|
Distribution / Recirculation / Piping Issue | View Details |
| – |
GSW water heater emits a rotten egg or sulfur smell from hot water taps
|
Bacterial Reaction with Anode Rod | View Details |
| – |
GSW water heater leaks from the drain valve at the bottom of the tank
|
Leaking Drain Valve | View Details |
| – |
GSW water heater leaks from the side or bottom of the tank body (not from fittings)
|
Tank Corrosion / Inner Tank Rupture | View Details |
| – |
GSW water heater leaks from the top around the hot or cold connections
|
Leaking Nipple / Dielectric Union / Dip Tube Connection | View Details |
| – |
GSW water heater makes popping, rumbling, or banging noises during heating
|
Sediment Boiling / Scale Buildup | View Details |
| – |
GSW water heater outer jacket is very hot to the touch or insulation seems inadequate
|
Insulation Degradation / Overheating | View Details |
| – |
GSW water heater produces discolored (rusty or brown) hot water
|
Internal Corrosion / Anode Depletion | View Details |
| – |
GSW water heater shows signs of backdrafting (soot around draft hood, melted plastic, or exhaust smell)
|
Vent Draft / Combustion Spillage | View Details |
| – |
GSW water heater T&P (temperature and pressure) relief valve is dripping or discharging water
|
Excessive Pressure / Temperature or Faulty T&P Valve | View Details |
| – |
GSW water heater trips the GFCI or AFCI outlet/breaker intermittently
|
Ground Fault / Electrical Leakage | View Details |
No matching codes found