E011
GSW Stuck Pressure Switch / Vent Proving Fault

GSW power vent water heater displays E011 and the blower runs continuously without firing

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Pressure switch stuck closed, Shorted pressure switch wiring, Control board logic fault, Incorrect vent slope causing water accumulation

How to Fix / Troubleshooting

Safety: Turn off power and gas. Do not operate the heater with a suspected venting fault.

  • Inspect pressure switch: Locate the round pressure switch near the blower. Disconnect the tubing and wiring. Gently tap the switch body to free a stuck diaphragm.
  • Check tubing and vent for water: Remove the tubing and check for water. Drain any condensate from low spots in the vent and correct vent slope to ensure proper drainage.
  • Test switch continuity (advanced): With no call for heat and no blower running, the switch should be open. If it reads closed, replace the pressure switch with a GSW-approved part.
  • Wiring inspection: Look for shorted or crossed wires between the pressure switch and control board. Repair as needed.
  • Control board: If a new switch behaves the same and wiring is correct, the control board may be misreading the signal and should be replaced by a technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Pressure Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements