E009
GSW Ignition Retry Lockout

GSW power vent water heater displays E009 and the unit locks out after several failed starts

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Intermittent igniter, Marginal flame sensor signal, Weak gas supply, Control board timing fault

How to Fix / Troubleshooting

Safety: Turn off gas and power before servicing. Avoid repeated manual resets without addressing the cause.

  • Clean and inspect flame sensor: Remove and clean the flame rod with fine abrasive pad. Ensure it is properly positioned in the burner flame.
  • Check igniter performance: Observe ignition (through sight glass) after restoring power and gas. If the igniter glows weakly or spark is inconsistent, replace the igniter assembly.
  • Verify gas supply: Confirm other gas appliances operate normally. If flames are small or unstable, have a gas technician check inlet pressure and regulator operation.
  • Reset control: Follow the GSW manual to clear lockout (often by cycling power or pressing a reset button). If E009 returns frequently, the control board or gas valve may require replacement by a qualified technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Igniter Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements