GSW Distribution / Recirculation / Piping Issue

GSW water heater does not meet temperature at distant fixtures but is hot near the tank

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Long pipe runs without recirculation, Cross-connection with cold line, Failing recirculation pump, Undersized hot water piping

How to Fix / Troubleshooting

Safety: No direct heater hazard, but avoid raising tank temperature excessively to compensate.

  • Check temperature at tank outlet: Measure hot water temperature directly at the heater to confirm it meets setpoint.
  • Inspect for cross-connections: A mis-plumbed mixing valve or single-handle faucet can mix cold into the hot line. Have a plumber test and correct.
  • Recirculation system: If present, verify the recirculation pump is running and check any check valves for proper operation.
  • Insulate piping: Add insulation to long hot water runs to reduce heat loss.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Recirculation Pump
Check Price on Amazon

We may earn a commission from links on this page.