E013
John Wood
Flame Rollout / Combustion Chamber Overheat
John Wood electronic gas water heater displays E013 and the burner shuts off shortly after lighting; strong flame rollout observed
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked burner orifice or ports, Blocked heat exchanger or flue passages, Failed or tripped flame rollout switch, Incorrect gas pressure
How to Fix / Troubleshooting
Danger: Flame rollout is a serious fire and CO hazard. Turn off gas and power immediately. Do not operate the heater until the cause is corrected.
- 1. Inspect rollout switch: Locate the flame rollout switch near the burner opening. If it is a manual-reset type, press the reset button once after the unit has cooled. If it trips again, do not reset—find and fix the cause.
- 2. Clean burner: Remove the burner assembly and clean all ports with a soft brush and compressed air. Do not enlarge the ports.
- 3. Check combustion chamber: Look for debris, insulation, or foreign objects inside the combustion chamber and remove them.
- 4. Vent and flue inspection: Ensure the flue and heat exchanger are not blocked. This step is best performed by a qualified technician with proper tools.
- 5. Gas pressure verification: Have a licensed gas technician measure inlet and manifold gas pressure and adjust or correct supply issues as needed.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Flame Rollout Switch
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements