John Wood
John Wood Water Heaters Error Codes
Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.
Advertisements
E001
Electronic John Wood gas water heater will not ignite; display shows E001 and burner never lights
Ignition Failure Lockout
E002
John Wood power vent gas water heater shows E002 and the blower runs but burner does not light
Pressure Switch / Inducer Proving Failure
E003
Electronic John Wood gas water heater displays E003 and shuts down shortly after burner lights
Flame Loss / Flame Rectification Fault
E004
John Wood power vent water heater shows E004 and will not start; blower does not run
Blower Motor / Power Vent Failure
E005
John Wood electronic gas water heater shows E005 and shuts down; tank is very hot to the touch
Overheat / ECO (Energy Cut-Off) Trip
E006
John Wood power vent water heater displays E006 and shuts down during operation
Exhaust Overheat / Vent Temperature Fault
E007
John Wood electronic gas water heater shows E007 and will not operate after a power surge or outage
Control Board Communication / Internal Fault
E008
John Wood power vent water heater displays E008 and cycles off shortly after starting
Intake Air Restriction / Combustion Air Fault
E009
John Wood electronic gas water heater shows E009 and does not respond to temperature adjustments
User Interface / Keypad Failure
E010
John Wood electronic gas water heater displays E010 and shuts down; no hot water
Temperature Sensor Open/Short Circuit
E011
John Wood power vent water heater shows E011 and the burner shuts off randomly
Flue Gas Spill / Draft Safety Switch Trip
E012
John Wood electronic gas water heater shows E012 and will not ignite; igniter does not glow or spark
Igniter Circuit Failure
E013
John Wood electronic gas water heater displays E013 and the burner shuts off shortly after lighting; strong flame rollout observed
Flame Rollout / Combustion Chamber Overheat
E014
John Wood electronic gas water heater shows E014 and the burner does not light; gas odor may be present near unit
Gas Valve Fault / Stuck Closed or Open
E015
John Wood electronic gas water heater displays E015 and the burner cycles rapidly on and off
Short Cycling / Sensor Calibration Fault
E016
John Wood power vent water heater shows E016 and the blower runs continuously even when there is no hot water demand
Stuck Relay / Control Output Fault
E017
John Wood electronic gas water heater displays E017 and the burner will not light; code appears immediately on startup
Internal Self-Test Failure
E018
John Wood power vent water heater shows E018 and shuts down during windy conditions
Wind Pressure / Vent Pressure Fault
E019
John Wood electronic gas water heater displays E019 and the burner shuts off; condensate present around base on condensing model
Condensate Drain Fault
E020
John Wood electronic gas water heater shows E020 and the burner does not light; code appears after long idle period
Low Line Voltage / Power Supply Fault
Symptom
John Wood atmospheric gas water heater pilot will not stay lit; pilot lights briefly then goes out when knob is released
Thermocouple Failure / Pilot Safety Circuit Fault
Symptom
John Wood electric water heater has power but no hot water; elements test good
Thermostat Control Failure (Electric)
Symptom
John Wood electric water heater trips the circuit breaker repeatedly
Electrical Overload / Short Circuit
Symptom
John Wood FVIR (Flammable Vapor Ignition Resistant) gas water heater pilot will not light at all; no flame at pilot
Pilot Gas Supply / FVIR Air Intake Restriction
Symptom
John Wood FVIR gas water heater shuts off and will not relight after suspected flammable vapor event
FVIR Safety System Lockout
Symptom
John Wood gas water heater burner does not ignite even though pilot is lit and stable
Main Burner Ignition Failure
Symptom
John Wood gas water heater produces insufficient hot water; runs out quickly compared to normal
Recovery Rate / Capacity Deficiency
Symptom
John Wood power vent water heater blower runs but there is a strong exhaust smell in the mechanical room
Vent Leakage / Backdrafting
Symptom
John Wood water heater causes discolored (rusty or brown) hot water
Corrosion / Rust Contamination
Symptom
John Wood water heater emits a burning or electrical smell near the control area
Overheating Electrical Component
Symptom
John Wood water heater emits a rotten egg or sulfur smell from hot water taps
Hydrogen Sulfide Odor Reaction
Symptom
John Wood water heater frequently cycles on and off, causing temperature swings at taps
Short Cycling / Thermostat Hysteresis Issue
Symptom
John Wood water heater hot water pressure is significantly lower than cold water pressure
Restricted Hot Outlet / Scaling
Symptom
John Wood water heater hot water temperature fluctuates significantly during a single shower
Temperature Stability / Mixing Issue
Symptom
John Wood water heater leaks from the top around the hot or cold water connections
Leaking Nipple / Dielectric Union / Piping Joint
Symptom
John Wood water heater leaks water from the drain valve at the bottom of the tank
Leaking Drain Valve
Symptom
John Wood water heater makes a high-pitched whistling or hissing noise when heating
Restricted Flow / Partially Closed Valve
Symptom
John Wood water heater makes popping or rumbling noises during heating
Sediment Boiling / Scale Buildup
Symptom
John Wood water heater produces no hot water at all; burner or elements never turn on
No Heat / Complete Shutdown
Symptom
John Wood water heater tank is leaking from the side or bottom; rust stains visible
Tank Corrosion / Inner Tank Rupture
Symptom
John Wood water heater vibrates excessively or makes banging noises in the vent or piping
Water Hammer / Combustion or Vent Vibration
Symptom
Water leaking from the temperature and pressure (T&P) relief valve on a John Wood water heater
T&P Valve Discharge
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| E001 |
Electronic John Wood gas water heater will not ignite; display shows E001 and burner never lights
|
Ignition Failure Lockout | View Details |
| E002 |
John Wood power vent gas water heater shows E002 and the blower runs but burner does not light
|
Pressure Switch / Inducer Proving Failure | View Details |
| E003 |
Electronic John Wood gas water heater displays E003 and shuts down shortly after burner lights
|
Flame Loss / Flame Rectification Fault | View Details |
| E004 |
John Wood power vent water heater shows E004 and will not start; blower does not run
|
Blower Motor / Power Vent Failure | View Details |
| E005 |
John Wood electronic gas water heater shows E005 and shuts down; tank is very hot to the touch
|
Overheat / ECO (Energy Cut-Off) Trip | View Details |
| E006 |
John Wood power vent water heater displays E006 and shuts down during operation
|
Exhaust Overheat / Vent Temperature Fault | View Details |
| E007 |
John Wood electronic gas water heater shows E007 and will not operate after a power surge or outage
|
Control Board Communication / Internal Fault | View Details |
| E008 |
John Wood power vent water heater displays E008 and cycles off shortly after starting
|
Intake Air Restriction / Combustion Air Fault | View Details |
| E009 |
John Wood electronic gas water heater shows E009 and does not respond to temperature adjustments
|
User Interface / Keypad Failure | View Details |
| E010 |
John Wood electronic gas water heater displays E010 and shuts down; no hot water
|
Temperature Sensor Open/Short Circuit | View Details |
| E011 |
John Wood power vent water heater shows E011 and the burner shuts off randomly
|
Flue Gas Spill / Draft Safety Switch Trip | View Details |
| E012 |
John Wood electronic gas water heater shows E012 and will not ignite; igniter does not glow or spark
|
Igniter Circuit Failure | View Details |
| E013 |
John Wood electronic gas water heater displays E013 and the burner shuts off shortly after lighting; strong flame rollout observed
|
Flame Rollout / Combustion Chamber Overheat | View Details |
| E014 |
John Wood electronic gas water heater shows E014 and the burner does not light; gas odor may be present near unit
|
Gas Valve Fault / Stuck Closed or Open | View Details |
| E015 |
John Wood electronic gas water heater displays E015 and the burner cycles rapidly on and off
|
Short Cycling / Sensor Calibration Fault | View Details |
| E016 |
John Wood power vent water heater shows E016 and the blower runs continuously even when there is no hot water demand
|
Stuck Relay / Control Output Fault | View Details |
| E017 |
John Wood electronic gas water heater displays E017 and the burner will not light; code appears immediately on startup
|
Internal Self-Test Failure | View Details |
| E018 |
John Wood power vent water heater shows E018 and shuts down during windy conditions
|
Wind Pressure / Vent Pressure Fault | View Details |
| E019 |
John Wood electronic gas water heater displays E019 and the burner shuts off; condensate present around base on condensing model
|
Condensate Drain Fault | View Details |
| E020 |
John Wood electronic gas water heater shows E020 and the burner does not light; code appears after long idle period
|
Low Line Voltage / Power Supply Fault | View Details |
| – |
John Wood atmospheric gas water heater pilot will not stay lit; pilot lights briefly then goes out when knob is released
|
Thermocouple Failure / Pilot Safety Circuit Fault | View Details |
| – |
John Wood electric water heater has power but no hot water; elements test good
|
Thermostat Control Failure (Electric) | View Details |
| – |
John Wood electric water heater trips the circuit breaker repeatedly
|
Electrical Overload / Short Circuit | View Details |
| – |
John Wood FVIR (Flammable Vapor Ignition Resistant) gas water heater pilot will not light at all; no flame at pilot
|
Pilot Gas Supply / FVIR Air Intake Restriction | View Details |
| – |
John Wood FVIR gas water heater shuts off and will not relight after suspected flammable vapor event
|
FVIR Safety System Lockout | View Details |
| – |
John Wood gas water heater burner does not ignite even though pilot is lit and stable
|
Main Burner Ignition Failure | View Details |
| – |
John Wood gas water heater produces insufficient hot water; runs out quickly compared to normal
|
Recovery Rate / Capacity Deficiency | View Details |
| – |
John Wood power vent water heater blower runs but there is a strong exhaust smell in the mechanical room
|
Vent Leakage / Backdrafting | View Details |
| – |
John Wood water heater causes discolored (rusty or brown) hot water
|
Corrosion / Rust Contamination | View Details |
| – |
John Wood water heater emits a burning or electrical smell near the control area
|
Overheating Electrical Component | View Details |
| – |
John Wood water heater emits a rotten egg or sulfur smell from hot water taps
|
Hydrogen Sulfide Odor Reaction | View Details |
| – |
John Wood water heater frequently cycles on and off, causing temperature swings at taps
|
Short Cycling / Thermostat Hysteresis Issue | View Details |
| – |
John Wood water heater hot water pressure is significantly lower than cold water pressure
|
Restricted Hot Outlet / Scaling | View Details |
| – |
John Wood water heater hot water temperature fluctuates significantly during a single shower
|
Temperature Stability / Mixing Issue | View Details |
| – |
John Wood water heater leaks from the top around the hot or cold water connections
|
Leaking Nipple / Dielectric Union / Piping Joint | View Details |
| – |
John Wood water heater leaks water from the drain valve at the bottom of the tank
|
Leaking Drain Valve | View Details |
| – |
John Wood water heater makes a high-pitched whistling or hissing noise when heating
|
Restricted Flow / Partially Closed Valve | View Details |
| – |
John Wood water heater makes popping or rumbling noises during heating
|
Sediment Boiling / Scale Buildup | View Details |
| – |
John Wood water heater produces no hot water at all; burner or elements never turn on
|
No Heat / Complete Shutdown | View Details |
| – |
John Wood water heater tank is leaking from the side or bottom; rust stains visible
|
Tank Corrosion / Inner Tank Rupture | View Details |
| – |
John Wood water heater vibrates excessively or makes banging noises in the vent or piping
|
Water Hammer / Combustion or Vent Vibration | View Details |
| – |
Water leaking from the temperature and pressure (T&P) relief valve on a John Wood water heater
|
T&P Valve Discharge | View Details |
No matching codes found
Advertisements