E016
John Wood
Stuck Relay / Control Output Fault
John Wood power vent water heater shows E016 and the blower runs continuously even when there is no hot water demand
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blower relay stuck closed on control board, Shorted wiring causing constant blower power, Control board logic failure
How to Fix / Troubleshooting
Safety: Disconnect power before inspecting the control board and wiring.
- 1. Power cycle: Turn off power at the breaker for 5 minutes, then restore. If the blower starts immediately with no call for heat, suspect a stuck relay or wiring fault.
- 2. Wiring inspection: Check the blower power wires for shorts to line voltage that bypass the control board.
- 3. Listen for relay click: With the cover off (and using caution around live parts), listen for the blower relay clicking on and off when there is a call for heat. If the blower stays on regardless, the relay may be welded closed.
- 4. Replace control board: If the relay is stuck or the board is providing constant output, replace the main control board with the correct John Wood part.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control Board
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements