E03
Termet
Flue Gas Exhaust / Fan Failure
Water heater locks out with E03, fan may not start or stops quickly, no ignition attempt.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked concentric flue on Termet turbo model, Faulty fan motor, Defective fan speed sensor or wiring, Blocked condensate trap causing pressure switch fault
How to Fix / Troubleshooting
Safety: Switch OFF power and close the gas valve before working on the appliance. Risk of carbon monoxide if flue is obstructed.
- Check flue terminal: From outside, inspect the Termet flue terminal for ice, bird nests, leaves, or debris. Clear any obstruction without altering the flue length or slope.
- Inspect condensate trap: On condensing Termet models, locate the condensate trap at the bottom of the heat exchanger. Remove and clean it of sludge and debris, then refill with clean water before refitting.
- Fan operation: Remove the front cover and visually inspect the fan. Spin the impeller gently by hand (power OFF) to ensure it moves freely. Check for broken blades or foreign objects.
- Wiring check: Verify the plug connection from the fan to the main PCB is secure and not corroded.
- Test run: Restore power and demand hot water. Listen for the fan starting. If the fan does not run or is noisy, it likely needs replacement.
- Technician required: Replacement of the Termet flue fan assembly or pressure sensing components should be carried out by a qualified Termet service technician due to combustion safety checks required.