Termet Air Pressure Switch / Differential Pressure Fault

Water heater shows E08, fan runs but ignition does not occur, or unit shuts down during operation.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked air pressure tubing, Faulty air pressure switch on Termet flue system, Blocked flue or intake, Condensate backing up into pressure tubing

How to Fix / Troubleshooting

Safety: Turn OFF power and gas. Risk of flue gas spillage if the air/flue system is compromised.

  • Inspect silicone tubes: Locate the air pressure switch and its silicone tubes. Remove them and blow through gently to ensure they are clear. Replace any hardened or cracked tubes.
  • Check condensate: Make sure the condensate trap and drain are not blocked, as water can fill the pressure tubes.
  • Flue inspection: Visually inspect the flue for kinks, disconnections, or obstructions. Do not modify the flue length or configuration without following Termet guidelines.
  • Switch test: With a multimeter, check continuity of the pressure switch when the fan runs (this test is usually done by a technician). If it does not change state, replace the pressure switch.
  • Professional service: Because this fault affects combustion safety, final diagnosis and any flue modifications should be done by an authorized Termet service technician.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Air Pressure Switch