E13
Termet Temperature Regulation Fault

Heater shows E13, water temperature overshoots setpoint, then unit shuts down.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Sticking gas valve on Termet heater, Faulty outlet NTC sensor giving slow response, Control board PID regulation error, Limescale reducing heat transfer and causing overshoot

How to Fix / Troubleshooting

Safety: Hot water can cause scalding. Reduce set temperature before testing.

  • Descale heat exchanger: If in a hard water area, perform a chemical descaling of the Termet heat exchanger to restore proper heat transfer.
  • Check NTC sensors: Verify both flow and outlet NTC sensors are correctly clipped to pipes and have good thermal contact. Replace if readings are unstable.
  • Gas valve behavior: If the flame does not modulate down when approaching set temperature, the gas valve or control board may be faulty. This requires a technician to test and replace.
  • Recalibration: Some Termet models allow service-level calibration of temperature control; this should be done by an authorized service center.