Termet
Gas Flow / Burner Resonance Noise
Water heater emits a whistling or high-pitched noise when running.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Partially blocked burner injectors on Termet heater, Incorrect gas pressure, Loose burner mounting, Air intake resonance in flue system
How to Fix / Troubleshooting
Safety: Noise alone is not usually dangerous, but it may indicate combustion issues.
- Check flue and air intake: Ensure the flue terminal is not partially blocked and that the air intake is unobstructed.
- Inspect burner: Have a technician remove and clean the burner and injectors, checking for damage or distortion.
- Gas pressure: A qualified person should measure and adjust gas pressure to Termet's recommended values.
- Secure components: Tighten burner mounting screws and check that internal panels are not vibrating.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Burner Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements