Termet
Ignition Control / Safety Chain Interruption
Water heater fan runs but burner does not ignite, and no error code is displayed.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty air pressure switch on Termet heater, Open overheat thermostat, Loose safety circuit wiring, Control board not commanding gas valve
How to Fix / Troubleshooting
Safety: Do not bypass safety devices. They are critical for safe operation.
- Check safety chain: Inspect wiring to the overheat thermostat, air pressure switch, and other safety devices. Ensure all connectors are secure.
- Reset overheat stat: If your Termet model has a manual reset overheat thermostat, press the reset button after the unit has cooled.
- Air pressure switch: Verify that the silicone tubes are connected and not blocked. Replace the switch if it does not change state when the fan runs (technician task).
- PCB diagnosis: If all safety devices are closed but the gas valve is not energized, the control board may be faulty and require replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Air Pressure Switch
Check Price on Amazon