Autotrol
No power to control
Autotrol softener display is blank and unit is completely unresponsive
Advertisements
Possible Causes
Failed transformer, Tripped circuit or dead outlet, Loose low-voltage plug, Blown internal fuse or damaged control board
How to Fix / Troubleshooting
Safety: Use caution when working around electrical outlets.
- Check outlet: Test the wall outlet with another device to confirm power is present.
- Test transformer: Measure the output of the Autotrol transformer (typically 24 VAC). Replace the 24 VAC transformer if no output.
- Inspect low-voltage plug: Ensure the transformer plug is fully inserted into the control head and that the cord is not damaged.
- Internal fuse/board: If power is present at the control but the display is dead, the internal fuse or control board may be blown. Replace the control module as an assembly.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Autotrol electronic control board
Check Price on Amazon
We may earn a commission from links on this page.