Autotrol

Autotrol Water Softeners Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
Err 1
Control display shows “Err 1” and valve will not start a regeneration cycle
Motor or camshaft home position fault
Err 2
Control display shows “Err 2” and regeneration stops mid-cycle
Camshaft position not reached within timeout
Err 3
Display shows “Err 3” and valve remains in service position, no regeneration occurs
Control board timing or program memory fault
Err 4
Display shows “Err 4” and regeneration stops during brine draw or slow rinse
Brine draw failure / flow sensor timeout
Err 5
Display shows “Err 5” and valve remains in backwash or fast rinse position
Cycle step overrun / valve not advancing
Err 6
Display shows “Err 6” and time-of-day or remaining capacity does not update correctly
Flow meter / turbine sensor fault
Err 7
Display shows “Err 7” and unit does not keep correct time or loses settings
Power supply or backup battery fault
Err 8
Display shows “Err 8” and valve will not enter manual regeneration when button is pressed
Keypad or user interface fault
Err 9
Display shows “Err 9” and regeneration occurs at incorrect times or too frequently
Programming or sensor configuration error
Err br
Display shows “Err br” or “Brine Err” and unit aborts regeneration during brine fill or draw
Brine system malfunction detected by control
Err dAtA
Display shows “Err dAtA” or “Data Err” and control is unresponsive or stuck
Configuration or memory corruption
Err FL
Display shows “Err FL” or “Flow Err” when water is running
Flow rate out of range or inconsistent meter signal
H0
Display shows “H0” or “HO” and unit appears locked or in hold mode
Service hold / vacation mode active
Lo Br
Display shows “Lo Br” or “Low Brine” and softening performance is poor
Low brine concentration or insufficient brine volume
Lo Salt
Display shows “Lo Salt” or “Low Salt” and an audible alarm may sound
Low brine tank salt level warning
No dEAL
Display shows “No dEAL” or similar message and regeneration does not start on demand
Demand signal not received from meter
PF
Display shows “PF” or “Power Fail” and time-of-day is flashing
Power interruption detected
Symptom
Autotrol softener allows hard water to bypass during regeneration (no soft water available)
No bypass of hard water during regeneration or incorrect plumbing
Symptom
Autotrol softener brine tank does not draw down during brine draw step
No brine draw
Symptom
Autotrol softener brine tank overflows with water
Brine tank overfill
Symptom
Autotrol softener causes low water pressure throughout the house
Flow restriction through valve or media
Symptom
Autotrol softener causes water hammer or banging pipes during cycle changes
Rapid valve port switching causing pressure spikes
Symptom
Autotrol softener discharges water to drain continuously, even in service mode
Continuous drain flow
Symptom
Autotrol softener display is blank and unit is completely unresponsive
No power to control
Symptom
Autotrol softener display is on but segments are missing or unreadable
Display module failure
Symptom
Autotrol softener does not regenerate at all (no cycling) and there is no error code
No regeneration initiation
Symptom
Autotrol softener emits a constant humming sound but does not move through cycles
Stalled drive motor
Symptom
Autotrol softener leaks water from the top of the control valve
Control head external leak
Symptom
Autotrol softener makes loud clicking or grinding noises during regeneration
Drive train or cam assembly noise
Symptom
Autotrol softener never regenerates on demand, only on time clock (or not at all) despite water usage
Demand-initiated regeneration not functioning
Symptom
Autotrol softener produces salty-tasting water after regeneration
Excessive brine carryover into service
Symptom
Autotrol softener regenerates too frequently (daily or multiple times per day)
Excessive regeneration frequency
Symptom
Autotrol softener stuck in regeneration and will not return to service position
Valve fails to complete regeneration cycle
Symptom
Autotrol softener’s time-of-day clock drifts or loses time between power outages
Clock accuracy or backup failure
Symptom
No water enters the brine tank during regeneration (dry brine tank)
No brine refill
Symptom
Water leaks from around the Autotrol softener’s bypass valve or yoke
Bypass/yoke external leak
Symptom
Water leaks from the brine tank or brine line connections
Brine system leak
Symptom
Water remains hard even though the Autotrol softener appears to run normally
Loss of softening capacity / resin exhaustion
Advertisements