Autotrol Demand-initiated regeneration not functioning

Autotrol softener never regenerates on demand, only on time clock (or not at all) despite water usage

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Flow meter not sending pulses, Meter cable disconnected, Demand mode disabled in programming, Wrong meter type selected

How to Fix / Troubleshooting

Safety: Disconnect power before handling wiring.

  • Confirm demand mode: In the installer menu, ensure the control is set to demand-initiated regeneration and not fixed time clock only.
  • Check meter wiring: Inspect the meter cable from the Autotrol meter to the control head for damage and secure connections.
  • Test meter operation: Run water and watch the display for flow or remaining capacity changes. If none, clean or replace the turbine flow meter.
  • Control input test: If a known-good meter and cable still do not register, the meter input on the control board may be defective and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Autotrol meter cable
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements