Err br
Autotrol
Brine system malfunction detected by control
Display shows “Err br” or “Brine Err” and unit aborts regeneration during brine fill or draw
Advertisements
Possible Causes
Blocked brine line, Stuck brine float, Clogged injector, Air leak in brine fittings
How to Fix / Troubleshooting
Safety: Bypass the softener and relieve pressure before opening brine connections.
- Inspect brine tank: Check that the float assembly moves freely and is not encrusted with salt. Clean or replace the brine float assembly if sticking.
- Check brine line: Remove the brine line from both ends and flush with water. Replace if kinked or brittle.
- Clean injector and screen: Remove and clean the injector/nozzle-venturi and screen to restore proper suction.
- Check for air leaks: Ensure all brine fittings are tight and sealed. Air leaks can prevent brine draw and trigger errors.
- Test regeneration: After reassembly, run a manual regeneration and observe brine movement. Confirm the error does not return.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Autotrol brine float assembly
Check Price on Amazon
We may earn a commission from links on this page.