Err br
Autotrol Brine system malfunction detected by control

Display shows “Err br” or “Brine Err” and unit aborts regeneration during brine fill or draw

Advertisements

Possible Causes

Blocked brine line, Stuck brine float, Clogged injector, Air leak in brine fittings

How to Fix / Troubleshooting

Safety: Bypass the softener and relieve pressure before opening brine connections.

  • Inspect brine tank: Check that the float assembly moves freely and is not encrusted with salt. Clean or replace the brine float assembly if sticking.
  • Check brine line: Remove the brine line from both ends and flush with water. Replace if kinked or brittle.
  • Clean injector and screen: Remove and clean the injector/nozzle-venturi and screen to restore proper suction.
  • Check for air leaks: Ensure all brine fittings are tight and sealed. Air leaks can prevent brine draw and trigger errors.
  • Test regeneration: After reassembly, run a manual regeneration and observe brine movement. Confirm the error does not return.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Autotrol brine float assembly
Check Price on Amazon

We may earn a commission from links on this page.