Err 9
Autotrol
Programming or sensor configuration error
Display shows “Err 9” and regeneration occurs at incorrect times or too frequently
Advertisements
Possible Causes
Incorrect hardness or capacity settings, Wrong meter type selected, Flow sensor miswired, Corrupted programming
How to Fix / Troubleshooting
Safety: No internal high-voltage work is required, but unplug the unit if removing covers.
- Verify programming: Enter the installer menu and confirm that water hardness, capacity, reserve, and regeneration time are set according to the Autotrol manual and your water conditions.
- Check meter type: Ensure the correct meter type (turbine, paddle, etc.) is selected in the control programming for your specific Autotrol valve and meter assembly.
- Inspect meter wiring: Confirm the flow meter sensor is connected to the correct terminals and that there are no shorts or reversed polarity (for Hall-effect sensors).
- Factory reset: Perform a factory reset and re-enter all parameters if the error persists. If the control still behaves erratically, replace the electronic control board.
- Monitor operation: After adjustments, monitor regeneration frequency over several days to ensure it matches expected usage.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Autotrol electronic control board
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements