Autotrol
Demand signal not received from meter
Display shows “No dEAL” or similar message and regeneration does not start on demand
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Disconnected or failed meter cable, Incorrect meter type setting, Defective turbine sensor, Control board input failure
How to Fix / Troubleshooting
Safety: Shut off power before handling wiring.
- Check meter cable: Trace the cable from the Autotrol meter/turbine to the control head. Ensure both ends are firmly connected and the cable is not cut or abraded.
- Verify programming: Confirm that the control is set to demand-initiated regeneration and that the correct meter type is selected.
- Test meter function: Run water through the softener and watch the display for flow indication or meter pulses. If no flow is detected, remove and inspect the turbine flow meter for debris and clean or replace as needed.
- Replace faulty components: If a known-good meter and cable still do not register, the control board meter input is likely defective and should be replaced.