E14
Clearwater
Regeneration Inhibit / Lockout Fault
E14 error and the unit reports no regeneration for an extended period despite water usage.
Advertisements
Possible Causes
Regeneration lockout time window misprogrammed, Vacation mode enabled, Flow meter not registering usage, Control board logic fault
How to Fix / Troubleshooting
Safety first: No plumbing work is required for programming checks. Do not interrupt an active regeneration.
- Check vacation mode: Ensure the Clearwater controller is not in vacation or bypass mode. Disable any vacation setting.
- Review regen time window: In installer settings, confirm that regeneration is allowed daily and not restricted to days that never occur (e.g., only day 7 with day override off).
- Verify meter operation: Run water and confirm the display shows flow and remaining capacity decreasing.
- Force a manual regen: Start a manual regeneration to restore softening capacity, then monitor if automatic cycles resume.
If E14 persists and programming is correct, the Clearwater control board may need replacement.