Clearwater

Clearwater Water Softeners Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
E01
Control panel shows E01 and the softener will not start a regeneration cycle.
Inlet Water Supply Fault
E02
Display shows E02 and the unit stops mid-regeneration.
Brine Tank Low Salt / Empty Brine Fault
E03
E03 displayed and the softener does not advance through regeneration stages.
Motor / Drive Fault
E04
E04 appears and the display backlight may flicker; unit may reset randomly.
Low Voltage / Power Supply Fault
E05
E05 displayed and the softener regenerates at incorrect times or not at all.
Clock / Timekeeping Fault
E06
E06 error and water remains hard even after regeneration.
Flow Sensor / Meter Fault
E07
E07 displayed and the unit stops with water running to drain continuously.
Valve Position Error
E08
E08 appears and the brine tank overfills with water.
Brine Refill / Overflow Fault
E09
E09 displayed and no water flows to drain during backwash or brine draw.
Drain Line / Backwash Fault
E10
E10 error and the display shows extremely high or zero hardness readings (on models with built-in sensor).
Hardness Sensor Fault
E11
E11 displayed and the unit will not accept new settings or loses programming when unplugged.
Memory / EEPROM Fault
E12
E12 error and the unit displays a sensor temperature out-of-range message (on models with temperature monitoring).
Temperature Sensor Fault
E13
E13 displayed and the unit indicates excessive regeneration frequency or salt usage.
Excessive Regeneration / Programming Fault
E14
E14 error and the unit reports no regeneration for an extended period despite water usage.
Regeneration Inhibit / Lockout Fault
E15
E15 displayed and the unit indicates a resin tank pressure or leak fault (on models with pressure sensor).
Pressure / Leak Detection Fault
E16
E16 displayed and the unit reports a communication error between display and main board (on modular models).
Communication Bus Fault
E17
E17 error and the unit indicates a brine draw timeout.
Brine Draw Timeout Fault
E18
E18 displayed and the unit indicates a salt level sensor error (on models with electronic salt sensor).
Salt Level Sensor Fault
E19
E19 error and the unit indicates an internal software fault.
Firmware / Software Fault
E20
E20 displayed and the unit indicates an overload or short on an auxiliary output (e.g., brine pump or external valve).
Auxiliary Output Overcurrent Fault
Symptom
Brine tank has water but salt level does not go down over time.
Salt Bridge / Salt Mushing
Symptom
Clearwater softener brine tank is dry (no water) even right before regeneration.
No Brine Refill
Symptom
Clearwater softener causes iron staining or sulfur odor even though hardness is reduced.
Resin Fouling / Inadequate Pretreatment
Symptom
Clearwater softener causes noticeable drop in water pressure throughout the house.
Flow Restriction Through Softener
Symptom
Clearwater softener display is blank or unresponsive, but outlet has power.
No Display / Dead Control Panel
Symptom
Clearwater softener display works but buttons do not respond or respond intermittently.
Keypad / User Interface Failure
Symptom
Clearwater softener does not draw brine during regeneration (brine level stays the same).
No Brine Draw
Symptom
Clearwater softener emits a constant hissing or trickling sound even when not regenerating.
Continuous Bypass or Internal Leak
Symptom
Clearwater softener installed in cold climate and stops working after freezing temperatures.
Freeze Damage
Symptom
Clearwater softener installed, but water is still supplied unsoftened (no change when bypass is toggled).
Incorrect Plumbing / Cross-Connection
Symptom
Clearwater softener is stuck in regeneration and continues to run water to drain.
Stuck in Regeneration Cycle
Symptom
Clearwater softener leaks water around the control valve or tank neck.
Control Valve / Tank Neck Leak
Symptom
Clearwater softener makes grinding or clicking noises from the control head during regeneration.
Drive Gear Wear / Motor Strain
Symptom
Clearwater softener makes loud banging or hammering noises when changing cycles.
Water Hammer / Rapid Valve Closure
Symptom
Clearwater softener will not start a regeneration cycle automatically, but manual regeneration works.
Automatic Regeneration Failure
Symptom
Water has a salty taste immediately after regeneration.
Insufficient Rinse / Residual Brine
Symptom
Water remains hard at faucets even though the Clearwater water softener appears to run normally (no error code).
Resin Exhaustion / Ineffective Softening
Symptom
Water softener brine tank overflows or fills nearly to the top with water between cycles.
Brine Tank Overfill