E14
Foridra
Inlet Pressure Sensor / Overpressure Fault
E14 error and the unit indicates high inlet pressure or shuts down unexpectedly
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed pressure sensor on Foridra valve, Inlet pressure above rated maximum, Blocked pressure port, Sensor wiring fault
How to Fix / Troubleshooting
Safety: High water pressure can cause leaks or bursts. Close the inlet valve and relieve pressure before removing any components.
- Measure pressure: Use a pressure gauge on a nearby faucet to confirm actual inlet pressure. If above 80 psi (5.5 bar), install or adjust a pressure reducing valve.
- Inspect sensor port: Locate the pressure sensor on the Foridra valve head and ensure its sensing port is not clogged with scale or debris. Clean gently if needed.
- Check wiring: Verify the sensor connector is secure and the cable is undamaged.
- Replace sensor: If readings are clearly wrong compared to the gauge, replace the Foridra pressure sensor module.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Foridra inlet pressure sensor
Check Price on Amazon