E15
Foridra
Low Pressure / Pressure Sensor Fault
E15 error and the unit reports low inlet pressure or will not start regeneration
Advertisements
Possible Causes
Actual low supply pressure, Clogged inlet pre-filter, Faulty Foridra pressure sensor, Air in inlet line
How to Fix / Troubleshooting
Safety: Turn off power before working on plumbing. Relieve pressure slowly.
- Check other fixtures: Confirm whether low pressure affects the whole house. If so, address the main supply or well system.
- Inspect pre-filter: If a sediment or carbon filter is installed before the Foridra softener, replace or clean the cartridge.
- Bleed air: Open a nearby faucet and slowly open the inlet valve to the softener to purge air from the lines.
- Sensor test: Compare the pressure reading (if displayed) with a mechanical gauge. If they differ significantly, replace the Foridra pressure sensor.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Foridra inlet pressure sensor
Check Price on Amazon
We may earn a commission from links on this page.