Possible Causes
How to Fix / Troubleshooting
Safety first: Depressurize the system before removing any screens or opening the valve.
Check valves:
- Verify the bypass valve is fully in SERVICE.
- Ensure upstream and downstream shutoff valves are fully open.
Inlet screen and prefilter:
- Inspect and clean any inlet screen on the control valve.
- Replace or clean any sediment prefilter cartridges upstream of the softener.
Resin condition:
- If iron or sediment has fouled the resin, perform a resin cleaning with an approved cleaner.
- Run a manual regeneration and recheck flow.
Resolution: If flow remains low, the resin bed may be severely fouled or the internal distributor may be blocked, requiring resin replacement and inspection of the distributor tube and screens.