Kinetico Low Water Pressure / Flow Restriction

Noticeable drop in water pressure or flow at faucets after the Kinetico softener.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Clogged inlet screen, Fouled resin bed, Partially closed bypass or shutoff valve, Plugged drain line causing incomplete backwash

How to Fix / Troubleshooting

Safety first: Depressurize the system before removing any screens or opening the valve.

Check valves:

  • Verify the bypass valve is fully in SERVICE.
  • Ensure upstream and downstream shutoff valves are fully open.

Inlet screen and prefilter:

  • Inspect and clean any inlet screen on the control valve.
  • Replace or clean any sediment prefilter cartridges upstream of the softener.

Resin condition:

  • If iron or sediment has fouled the resin, perform a resin cleaning with an approved cleaner.
  • Run a manual regeneration and recheck flow.

Resolution: If flow remains low, the resin bed may be severely fouled or the internal distributor may be blocked, requiring resin replacement and inspection of the distributor tube and screens.