ERR 07
Pentair Brine Valve / Refill Circuit Error

ERR 07 displayed; unit may be stuck in brine fill or brine draw and not complete regeneration.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck brine refill valve in Pentair control head, Clogged refill flow control, Failed brine solenoid (on electronic valves with separate solenoid), Control board output failure

How to Fix / Troubleshooting

Safety: Shut off water and disconnect power. Depressurize the system before opening the valve body.

  • Inspect brine valve: Remove the brine valve assembly from the Pentair control valve (usually on the side or rear). Check for debris, iron sludge, or scale preventing full movement.
  • Clean flow control: Locate the brine refill flow control orifice. Remove and flush under running water. Use a soft brush; do not enlarge the orifice.
  • Solenoid test (if equipped): If your Pentair model uses an external brine solenoid, apply 24V (or rated voltage) briefly to the coil and listen for a click. No click indicates a failed solenoid coil.
  • Check board output: In diagnostic mode, command a brine fill and measure voltage at the solenoid terminals. If no voltage is present while the board calls for fill, the control board output is likely defective.
  • Replace parts: Replace a stuck or leaking Pentair brine valve assembly or brine solenoid valve as needed. If outputs are dead, replace the Pentair electronic control board.
  • Test regeneration: Reassemble, restore water and power, and run a manual regeneration to confirm proper brine fill and draw.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Pentair brine valve assembly
Check Price on Amazon