ERR 08
Pentair
Salt Level Sensor / Brine Tank Probe Error
ERR 08 on display; softener may not detect salt level or may show incorrect salt alarm status.
Advertisements
Possible Causes
Failed Pentair salt level sensor, Disconnected or damaged sensor wiring, Heavy salt bridging preventing sensor contact, Incorrect sensor type configured
How to Fix / Troubleshooting
Safety: Unplug the unit before working with electrical connections. Wear gloves when handling salt.
- Check sensor wiring: Locate the salt level sensor or brine tank probe and follow its cable to the control head. Ensure connectors are fully seated and wires are not cut or pinched.
- Inspect sensor: Remove the sensor from the brine tank. Clean off salt crust or sludge with warm water and a soft brush. Do not use harsh chemicals.
- Check for salt bridge: Look for a hard crust of salt spanning the tank above the water level. Break it up with a broom handle, being careful not to damage the tank or float assembly.
- Programming: Verify in the installer menu that the correct salt sensor option is selected (if your Pentair controller supports multiple sensor types).
- Replace sensor: If the error persists and wiring is intact, replace the Pentair salt level sensor / brine tank probe.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Pentair salt level sensor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements