ERR 08
Pentair Salt Level Sensor / Brine Tank Probe Error

ERR 08 on display; softener may not detect salt level or may show incorrect salt alarm status.

Advertisements

Possible Causes

Failed Pentair salt level sensor, Disconnected or damaged sensor wiring, Heavy salt bridging preventing sensor contact, Incorrect sensor type configured

How to Fix / Troubleshooting

Safety: Unplug the unit before working with electrical connections. Wear gloves when handling salt.

  • Check sensor wiring: Locate the salt level sensor or brine tank probe and follow its cable to the control head. Ensure connectors are fully seated and wires are not cut or pinched.
  • Inspect sensor: Remove the sensor from the brine tank. Clean off salt crust or sludge with warm water and a soft brush. Do not use harsh chemicals.
  • Check for salt bridge: Look for a hard crust of salt spanning the tank above the water level. Break it up with a broom handle, being careful not to damage the tank or float assembly.
  • Programming: Verify in the installer menu that the correct salt sensor option is selected (if your Pentair controller supports multiple sensor types).
  • Replace sensor: If the error persists and wiring is intact, replace the Pentair salt level sensor / brine tank probe.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Pentair salt level sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements