ERR SALT
Pentair Salt Sensor Communication / Range Error

Display shows ERR SALT or SALT SENSOR ERROR; salt level reading is erratic or stuck.

Advertisements

Possible Causes

Shorted or open salt sensor, Wrong sensor type selected, Corroded sensor connector, Damaged control board sensor circuit

How to Fix / Troubleshooting

Safety: Disconnect power before unplugging or plugging any sensor cables.

  • Visual inspection: Remove the brine tank lid and inspect the salt sensor wiring and connector. Clean any corrosion and ensure a tight fit.
  • Check configuration: In the installer menu, verify that the salt sensor feature is enabled only if a sensor is installed, and that the correct sensor type is selected.
  • Continuity test: With the sensor unplugged, measure resistance across its terminals. An infinite or zero reading (depending on sensor type) may indicate failure. Compare to Pentair service specs.
  • Bypass test: Temporarily disable the salt sensor feature in programming (if allowed). If ERR SALT disappears, the sensor is likely faulty.
  • Replace sensor or board: Replace the Pentair salt level sensor if defective. If a new sensor still triggers ERR SALT, replace the Pentair electronic control board.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Pentair salt level sensor
Check Price on Amazon

We may earn a commission from links on this page.