Scalemaster
Brine Tank Overfill
Brine tank full of water and occasionally overflows
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck brine refill valve in Scalemaster control head, Blocked brine line preventing proper draw, Air check valve not closing, Incorrect float level setting in brine well
How to Fix / Troubleshooting
Safety first: Disconnect power and close inlet valve. Mop up any spilled brine promptly to avoid corrosion.
Step-by-step checks:
- 1. Manually lower water level: Use a jug or wet vacuum to remove excess brine until just above the salt grid.
- 2. Inspect air check valve: Remove the brine well cap and lift out the float/air check assembly. Clean off salt sludge and ensure the float moves freely.
- 3. Check for blocked injector: A blocked injector can prevent brine draw, leaving refill water in the tank. Clean the injector as per the manual.
- 4. Verify float height: Ensure the float assembly is set to the correct height for your model so it shuts off refill at the right level.
If overfilling continues, the internal refill valve may be leaking and should be serviced by a technician.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Brine Float / Air Check Valve and Refill Valve
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements