Scalemaster Flow Restriction Through Softener

Water pressure at taps drops significantly when softener is in service

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked inlet strainer on Scalemaster valve, Fouled resin bed with iron or debris, Partially closed isolation valve, Undersized pipework or hoses

How to Fix / Troubleshooting

Safety first: Isolate water and relieve pressure before removing strainers or hoses.

Step-by-step checks:

  • 1. Compare in bypass: Place the softener in bypass. If pressure improves, the restriction is within the softener.
  • 2. Clean inlet strainer: Remove and rinse the inlet mesh filter.
  • 3. Check valves fully open: Confirm inlet and outlet isolation valves are fully open.

Severe fouling of the resin bed may require professional cleaning or resin replacement.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Inlet Strainer / Resin Bed
Check Price on Amazon