Scalemaster
Flow Restriction Through Softener
Water pressure at taps drops significantly when softener is in service
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked inlet strainer on Scalemaster valve, Fouled resin bed with iron or debris, Partially closed isolation valve, Undersized pipework or hoses
How to Fix / Troubleshooting
Safety first: Isolate water and relieve pressure before removing strainers or hoses.
Step-by-step checks:
- 1. Compare in bypass: Place the softener in bypass. If pressure improves, the restriction is within the softener.
- 2. Clean inlet strainer: Remove and rinse the inlet mesh filter.
- 3. Check valves fully open: Confirm inlet and outlet isolation valves are fully open.
Severe fouling of the resin bed may require professional cleaning or resin replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Inlet Strainer / Resin Bed
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements