F04
Vaillant Flow Meter / Turbine Signal Fault

F04 displayed and no water flow is registered even when taps are open

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked turbine in flow meter, Damaged Hall sensor, Loose or corroded wiring to flow meter, Faulty control PCB input

How to Fix / Troubleshooting

Safety: Turn off power and close the inlet valve before removing any flow components.

Steps:

  • Confirm actual water flow: Open a tap downstream of the softener. If water flows normally but the display shows zero consumption, the issue is with the flow measurement system.
  • Remove and inspect flow meter: The flow meter is typically integrated into the inlet block. Remove it according to the service manual. Check the turbine wheel for scale, sand, or debris. It should spin freely with a gentle puff of air.
  • Clean and descale: Soak the turbine and housing in a mild descaler (citric acid or white vinegar), then rinse thoroughly. Do not scratch the surfaces.
  • Check electrical connection: Inspect the Hall sensor connector and cable for damage or corrosion. Reseat the connector on the control board.
  • Test sensor: With a multimeter (if competent), verify that the Hall sensor receives supply voltage and produces pulses when the turbine is rotated. Replace the flow meter assembly if no pulses are generated.
  • Reassemble and reset: Refit the flow meter, restore water and power, clear the F04 code, and verify that flow is now registered on the display.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Inlet Flow Meter / Turbine Sensor
Check Price on Amazon