Vaillant Water Softeners Error Codes
Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.
Advertisements
F01
Display shows F01 and the softener does not start a regeneration cycle
Inlet Water Supply Fault
F02
F02 displayed and unit does not draw brine during regeneration
Brine Suction / Injector Fault
F03
F03 error and softener stuck in regeneration or cannot complete cycle
Motor / Valve Positioning Fault
F04
F04 displayed and no water flow is registered even when taps are open
Flow Meter / Turbine Signal Fault
F05
F05 error and the unit reports low salt even when the brine tank is full
Salt Level Sensor Fault
F06
F06 displayed and the softener does not regenerate at the programmed time
Real-Time Clock / Programming Fault
F07
F07 error and the display shows abnormal temperature or freezes during regeneration
Control Board Overtemperature / Sensor Fault
F08
F08 displayed and the unit reports excessive water usage or continuous flow when no taps are open
Continuous Flow / Possible Leak Detection
F09
F09 error and the unit cannot enter service mode after regeneration
Valve Home Position Not Detected
F10
F10 displayed and the softener reports high internal pressure or shuts down unexpectedly
Overpressure / Pressure Sensor Fault
F11
F11 error and the unit aborts regeneration during brine fill or rinse
Drain Line / Backwash Flow Fault
F12
F12 displayed and the unit reports resin capacity error or cannot calculate remaining capacity
Resin Capacity / Programming Error
F13
F13 error and the unit indicates brine tank overfill or high water level
Brine Tank Overfill / Float Fault
F14
F14 displayed and the unit reports communication error between display and main board
Internal Communication Fault
F15
F15 error and the softener reports sensor supply fault or multiple sensor errors simultaneously
Low Voltage Sensor Supply Fault
Symptom
Brine tank fills with water and overflows periodically without any error code
Brine Tank Overfilling
Symptom
Display is on but buttons do not respond or respond intermittently
Keypad / User Interface Fault
Symptom
Noticeable drop in water pressure at taps when softener is in service
Flow Restriction Through Softener
Symptom
Softener allows hard water through during regeneration (no soft water bypass)
Incorrect Bypass / Plumbing Configuration
Symptom
Softener causes water hammer or banging noises in pipes during regeneration
Hydraulic Shock During Valve Switching
Symptom
Softener display is completely blank and unit is unresponsive
No Power to Control
Symptom
Softener does not draw brine during regeneration but no error code is shown
Silent Brine Draw Failure
Symptom
Softener does not start regeneration at the expected time (time-based model)
Regeneration Scheduling Issue
Symptom
Softener emits a persistent beeping or alarm tone without a visible error code
Hidden Alarm / Service Reminder
Symptom
Softener emits unusual odour from brine tank or softened water
Bacterial Growth / Contamination
Symptom
Softener frequently trips the electrical circuit breaker or blows fuses
Electrical Overload / Short Circuit
Symptom
Softener installed but water remains hard because unit is in permanent bypass
Bypass Left Engaged After Installation or Service
Symptom
Softener installed on hot water line by mistake, causing deformation or leaks
Incorrect Installation on Hot Supply
Symptom
Softener leaks water from around the control head or top of the resin cylinder
Control Head / Tank O-Ring Leak
Symptom
Softener makes loud clicking or grinding noises during regeneration
Drive Motor / Gear Train Wear
Symptom
Softener never regenerates on a metered model, even with high water usage
No Demand Regeneration
Symptom
Softener produces salty-tasting water immediately after regeneration
Insufficient Rinse After Brine Draw
Symptom
Softener regenerates too often, sometimes daily, even with low water usage
Over-Frequent Regeneration
Symptom
Softener resin tank sweats or shows condensation, with occasional drips onto the floor
Condensation on Cold Surfaces
Symptom
Softener uses salt very quickly and brine tank empties frequently
Excessive Salt Consumption
Symptom
Water leaking from brine line connections or around the brine well
Brine Line / Fitting Leak
Symptom
Water remains hard at taps even though the Vaillant softener appears to run normally (no error code)
Loss of Softening Capacity
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| F01 |
Display shows F01 and the softener does not start a regeneration cycle
|
Inlet Water Supply Fault | View Details |
| F02 |
F02 displayed and unit does not draw brine during regeneration
|
Brine Suction / Injector Fault | View Details |
| F03 |
F03 error and softener stuck in regeneration or cannot complete cycle
|
Motor / Valve Positioning Fault | View Details |
| F04 |
F04 displayed and no water flow is registered even when taps are open
|
Flow Meter / Turbine Signal Fault | View Details |
| F05 |
F05 error and the unit reports low salt even when the brine tank is full
|
Salt Level Sensor Fault | View Details |
| F06 |
F06 displayed and the softener does not regenerate at the programmed time
|
Real-Time Clock / Programming Fault | View Details |
| F07 |
F07 error and the display shows abnormal temperature or freezes during regeneration
|
Control Board Overtemperature / Sensor Fault | View Details |
| F08 |
F08 displayed and the unit reports excessive water usage or continuous flow when no taps are open
|
Continuous Flow / Possible Leak Detection | View Details |
| F09 |
F09 error and the unit cannot enter service mode after regeneration
|
Valve Home Position Not Detected | View Details |
| F10 |
F10 displayed and the softener reports high internal pressure or shuts down unexpectedly
|
Overpressure / Pressure Sensor Fault | View Details |
| F11 |
F11 error and the unit aborts regeneration during brine fill or rinse
|
Drain Line / Backwash Flow Fault | View Details |
| F12 |
F12 displayed and the unit reports resin capacity error or cannot calculate remaining capacity
|
Resin Capacity / Programming Error | View Details |
| F13 |
F13 error and the unit indicates brine tank overfill or high water level
|
Brine Tank Overfill / Float Fault | View Details |
| F14 |
F14 displayed and the unit reports communication error between display and main board
|
Internal Communication Fault | View Details |
| F15 |
F15 error and the softener reports sensor supply fault or multiple sensor errors simultaneously
|
Low Voltage Sensor Supply Fault | View Details |
| – |
Brine tank fills with water and overflows periodically without any error code
|
Brine Tank Overfilling | View Details |
| – |
Display is on but buttons do not respond or respond intermittently
|
Keypad / User Interface Fault | View Details |
| – |
Noticeable drop in water pressure at taps when softener is in service
|
Flow Restriction Through Softener | View Details |
| – |
Softener allows hard water through during regeneration (no soft water bypass)
|
Incorrect Bypass / Plumbing Configuration | View Details |
| – |
Softener causes water hammer or banging noises in pipes during regeneration
|
Hydraulic Shock During Valve Switching | View Details |
| – |
Softener display is completely blank and unit is unresponsive
|
No Power to Control | View Details |
| – |
Softener does not draw brine during regeneration but no error code is shown
|
Silent Brine Draw Failure | View Details |
| – |
Softener does not start regeneration at the expected time (time-based model)
|
Regeneration Scheduling Issue | View Details |
| – |
Softener emits a persistent beeping or alarm tone without a visible error code
|
Hidden Alarm / Service Reminder | View Details |
| – |
Softener emits unusual odour from brine tank or softened water
|
Bacterial Growth / Contamination | View Details |
| – |
Softener frequently trips the electrical circuit breaker or blows fuses
|
Electrical Overload / Short Circuit | View Details |
| – |
Softener installed but water remains hard because unit is in permanent bypass
|
Bypass Left Engaged After Installation or Service | View Details |
| – |
Softener installed on hot water line by mistake, causing deformation or leaks
|
Incorrect Installation on Hot Supply | View Details |
| – |
Softener leaks water from around the control head or top of the resin cylinder
|
Control Head / Tank O-Ring Leak | View Details |
| – |
Softener makes loud clicking or grinding noises during regeneration
|
Drive Motor / Gear Train Wear | View Details |
| – |
Softener never regenerates on a metered model, even with high water usage
|
No Demand Regeneration | View Details |
| – |
Softener produces salty-tasting water immediately after regeneration
|
Insufficient Rinse After Brine Draw | View Details |
| – |
Softener regenerates too often, sometimes daily, even with low water usage
|
Over-Frequent Regeneration | View Details |
| – |
Softener resin tank sweats or shows condensation, with occasional drips onto the floor
|
Condensation on Cold Surfaces | View Details |
| – |
Softener uses salt very quickly and brine tank empties frequently
|
Excessive Salt Consumption | View Details |
| – |
Water leaking from brine line connections or around the brine well
|
Brine Line / Fitting Leak | View Details |
| – |
Water remains hard at taps even though the Vaillant softener appears to run normally (no error code)
|
Loss of Softening Capacity | View Details |
No matching codes found
Advertisements