F12
Vaillant
Resin Capacity / Programming Error
F12 displayed and the unit reports resin capacity error or cannot calculate remaining capacity
Advertisements
Possible Causes
Incorrect hardness setting, Incorrect resin volume programmed, Corrupted control parameters, Control PCB memory fault
How to Fix / Troubleshooting
Safety: No hydraulic work is required for basic reprogramming.
Actions:
- Verify water hardness: Test the raw water hardness using a test kit or refer to the water supplier's data. Enter the correct value into the Vaillant control.
- Check resin volume setting: Ensure the programmed resin volume matches the installed cylinder size specified for your Vaillant model.
- Factory reset: If allowed by the manual, perform a factory reset of the control and re‑enter all parameters (time, hardness, capacity, regeneration type).
- Monitor operation: After reset, observe the unit over several days to confirm that capacity is calculated correctly and F12 does not reappear.
- PCB replacement: If F12 persists despite correct programming, the control PCB memory may be faulty and require replacement by a technician.
Advertisements
Repair Difficulty
Easy
2/5