E6
Auseo
User Interface / Touch Control Panel Fault
Display shows E6 and the touch buttons or temperature controls do not respond properly.
Advertisements
Possible Causes
Moisture intrusion into touch panel, Damaged touch PCB, Loose ribbon cable between UI and main board, Faulty capacitive touch sensor IC
How to Fix / Troubleshooting
Safety: Disconnect the Auseo wine cooler from power before removing the control panel.
Steps:
- Power reset: Unplug for 5–10 minutes, then reconnect. If E6 persists, continue.
- Inspect control panel: Remove the front control panel (usually held by clips or screws). Check for condensation, corrosion, or liquid spills on the touch PCB.
- Check ribbon cable: Ensure the flat ribbon cable between the user interface board and main control board is fully seated and not damaged.
- Dry and clean: If moisture is present, gently dry the area with a lint-free cloth and allow the panel to air dry completely before reassembly.
- Replace UI board: If buttons remain unresponsive and E6 continues, replace the touch control panel / user interface PCB specific to your Auseo model.
- Test: Reconnect power and verify that all buttons respond and the error code is cleared.
Note: Avoid spraying cleaners directly on the control panel; apply to a cloth instead to prevent future moisture damage.