Auseo

Auseo Wine Coolers Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
dF
Display alternates dF and temperature; unit may stop cooling periodically and ice may build up.
Defrost Mode Indication / Defrost Fault
E0
Display shows E0 and the wine cooler will not cool, interior fan may or may not run.
Cabinet Temperature Sensor Failure
E1
Display shows E1 and temperature reading is inaccurate or dashes, unit may overcool or not cool properly.
Evaporator Temperature Sensor Failure
E2
Display shows E2 and the compressor cycles erratically or not at all, temperature fluctuates widely.
Ambient Temperature Sensor Failure
E3
Display shows E3 and the compressor does not start, or starts then stops quickly; fan may still run.
Compressor Start Circuit / Relay Fault
E4
Display shows E4 and the interior fan does not run, or runs intermittently; cooling is weak and uneven.
Evaporator Fan Motor Failure
E5
Display shows E5 and the unit runs continuously or not at all; temperature overshoots setpoint.
Defrost Sensor or Defrost Circuit Error
E6
Display shows E6 and the touch buttons or temperature controls do not respond properly.
User Interface / Touch Control Panel Fault
E7
Display shows E7 and the interior light stays on or will not turn on, sometimes affecting cooling.
Door Switch or Door Sensor Fault
E8
Display shows E8 and the unit is excessively noisy or the compressor does not run smoothly.
Compressor Overload / Overheat Protection Error
E9
Display shows E9 and the unit does not cool despite fans running; compressor may be off.
Low Voltage or Power Supply Error
Er
Display shows Er or flashes all segments; unit may not respond to button presses.
General Control Board Communication Error
F1
Display shows F1 and the upper zone of a dual-zone Auseo wine cooler does not maintain temperature.
Upper Zone Temperature Sensor Fault
F2
Display shows F2 and the lower zone of a dual-zone Auseo wine cooler does not maintain temperature.
Lower Zone Temperature Sensor Fault
F3
Display shows F3 and one zone of the dual-zone cooler overcools or undercools intermittently.
Dual-Zone Mixing Fan or Air Damper Fault
H1
Display shows H1 and the cabinet temperature is much higher than the setpoint; unit may not cool at all.
High Temperature Alarm / Cooling Failure
L1
Display shows L1 and the cabinet temperature is much lower than setpoint; bottles may be icing.
Low Temperature Alarm / Overcooling
Symptom
Cabinet exterior sides feel very hot to the touch during operation.
Excessive Heat Rejection / Ventilation Problem
Symptom
Cabinet interior feels excessively dry; corks appear to be drying out.
Low Humidity Inside Wine Cooler
Symptom
Cabinet interior feels too humid; labels peeling or mold forming despite normal temperature.
High Internal Humidity
Symptom
Clicking sound from the rear and the compressor repeatedly tries to start but fails.
Compressor Hard Start / Overload Cycling
Symptom
Condensation or fogging on the inside of the glass door.
High Humidity Ingress / Door Seal or Environment Issue
Symptom
Display is lit but buttons do not respond or respond intermittently.
Unresponsive Touch Controls
Symptom
Dual-zone wine cooler shows large temperature difference between zones even when set similarly.
Zone Imbalance / Airflow Distribution Issue
Symptom
Excessive frost or ice buildup on the back interior wall or around the evaporator; cooling gradually worsens.
Defrost System Failure
Symptom
Glass door appears fogged between the panes and cannot be wiped clear.
Failed Door Glass Seal / Insulated Glass Unit Leak
Symptom
High-pitched squealing or grinding noise from inside the cabinet.
Evaporator Fan Bearing Wear or Obstruction
Symptom
Interior light not working even though the cooler runs normally.
Interior LED Lighting Failure
Symptom
Interior light stays on even when the door is closed, causing the cabinet to warm up.
Stuck Door Switch or Light Control Fault
Symptom
Loud humming, rattling, or vibrating noise during operation.
Excessive Vibration / Mechanical Noise
Symptom
Moldy or musty odor inside the wine cooler.
Microbial Growth on Interior Surfaces and Drain System
Symptom
Shelves difficult to slide or come off tracks; bottles feel unstable.
Shelf Track or Rail Wear
Symptom
Strong chemical or burning smell coming from the rear of the wine cooler.
Overheating Electrical Component
Symptom
Temperature display is flashing but no specific error code is shown.
Temperature Alarm Without Specific Fault Code
Symptom
Warm air felt around the door edges; condensation forming on the outside of the glass door.
Door Gasket Seal Failure
Symptom
Water pooling at the bottom of the wine cooler or leaking onto the floor.
Drainage System Blockage or Condensation Leak
Symptom
Wine cooler not cooling at all; interior light works but compressor and fans are off, no error code displayed.
No Cooling / Control or Start Circuit Failure
Symptom
Wine cooler runs but does not get cold enough; temperature stays above setpoint without any error code.
General Cooling Performance Loss
Symptom
Wine cooler runs continuously and becomes too cold even at higher set temperatures; no error code.
Thermostat / Temperature Control Failure
Symptom
Wine cooler will not power on at all; display is blank and no lights or sounds.
No Power / Dead Appliance
Advertisements