Auseo
No Cooling / Control or Start Circuit Failure
Wine cooler not cooling at all; interior light works but compressor and fans are off, no error code displayed.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty main control board, Failed compressor start relay, Open thermal fuse on control board, Broken wiring to compressor
How to Fix / Troubleshooting
Safety: Disconnect power before accessing the rear or control panel.
Steps:
- Confirm power: Verify that the outlet has power and that the unit is switched on and not in demo mode (if applicable).
- Check temperature setting: Ensure the setpoint is below room temperature so the unit should be calling for cooling.
- Inspect control board: Remove the rear panel and look for blown fuses or burnt components on the main PCB.
- Check compressor start components: Inspect the compressor start relay and overload protector for damage. Replace if burnt or rattling.
- Test continuity: With power off, check wiring continuity from the control board to the compressor and fans.
- Replace main PCB: If wiring and start components are good but the board does not send power to the compressor or fan, replace the main control board.
Note: If you are not comfortable testing live voltages, contact a professional technician.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control Board
Check Price on Amazon