E7
Auseo
Door Switch or Door Sensor Fault
Display shows E7 and the interior light stays on or will not turn on, sometimes affecting cooling.
Advertisements
Possible Causes
Failed magnetic reed switch, Misaligned door magnet, Broken door switch wiring, Faulty door sensor input on main PCB
How to Fix / Troubleshooting
Safety: Unplug the unit before working around the door frame wiring.
How to fix:
- Locate door sensor: On many Auseo wine coolers, a magnetic reed switch is hidden in the cabinet frame, with a magnet in the door. Others use a mechanical plunger switch.
- Check alignment: Ensure the door closes fully and the magnet lines up with the sensor area. Adjust door hinges if the door is sagging.
- Test switch: If accessible, disconnect the switch and test continuity with a multimeter while opening and closing the door (or moving a magnet near a reed switch). The reading should change between open and closed.
- Inspect wiring: Look for pinched or broken wires near the top or side of the cabinet where the harness runs.
- Replace faulty parts: Install a new door reed switch or door plunger switch if defective. Ensure the door magnet is secure and correctly positioned.
- Verify operation: Restore power and confirm that the interior light and door-ajar indicator behave normally and E7 is cleared.
Tip: A stuck-on light can heat the cabinet and cause poor cooling; address this fault promptly.